GTC Series 120-800KVA Online UPS 3 Phase
Online UPS manufactured and supplied by SM-VOLTSMART is the most preferred online UPS.
Features
- Digital Control System
- High output Power Factor
- Dual Input Operation
- Advance Battery Management
- Warranty - 1 Year
Product Description
GTC Series uninterruptible power supply (UPS) with innovative 3 level Technology is a true on-line double conversion, three-phase UPS system that provides one of the highest level energy efficiencies in the industry. With its latest Three level inverter & rectifier design GTC Series brings the newest power conversion technology and delivers efficiency up to 96.5% at 50-75% load operation which is the most common operating range. This ultra high system efficiency provides considerable cost savings in comparison to the traditional transformer less UPSʼs with 93% efficiency.
Special Features
- True Online, Three Level IGBT Rectifier & Inverter Technology
- High Output Power Factor 0.9
- On Line-Double Conversion Technology (Class VFI-SS-111)
- DSP Control
- Ultra High Efficiency 96.5%
- Low Input Current THDi (<3%)
- High Input Power Factor (>0.99)
- Dual Input
- DBST (Dual Bus Synchronisation Technology) enable multiple UPS in Parallel to work like single UPS
- Optional DC/DC Charger/Booster
- Wide Input Voltage Range
- Advance Battery Management
- Parallel upto 8 Units
- 500 Real Time Event Log with Detailed Parameters
- Static & Manual Bypass Operation
- Small Footprint and Easy Maintenance
- Advance Communication Capabilities
- Perfect Generator Compatibility
- External Battery Temperature Facility
- Isolation Transformer Compatible
Application
Industries, Medical & Healthcare, IT, Networking & Security
Technical Specifications
Capacity | 120 KVA, 160 KVA, 200 KVA, 250 KVA, 300 KVA, 400 KVA, 500 KVA, 600 KVA, 800 KVA |
Input Voltage Range | 380V / 400V / 415V AC +25% –30% (3P+N+PE) |
Input Frequency Range | 50 / 60 Hz ± 10% Auto Sensing |
Power Factor | >0.99 |
Harmonic Distortion (THDi) | <3% |
Output Voltage Range | 380V / 400V / 415VAC 3P+N ±1% |
Output Frequency Range | Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode |
THD (THDv) | Linear Load <2%; Non-Linear Load <5% |
Efficiency | Up to 96.5% Dual Conversion Mode, 99% ECO Mode |
Crest Factor | 3:1 |
Overload | 110% for 60 Min, 125% for 10 Min, 150% for 1 Min and 150% for 300 ms |
Battery Voltage | ± 360V DC, ± 372V DC Configurable |
Charge Value | Nominal 0.1C, Configurable 0.2C |
Technology | 3Level IGBT based Rectifier, Inverter VFI-SS-111 |
IP Protection | IP 20 |
Walk-in Time | 0~60 Sec (Configurable) |
Parallel | Parallel upto 8 Units |
Alarm / Protection | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low |
Display LED + GLCD | Input Voltage, frequency, Input Power KVA / KW, Output Voltage Frequency, Input Power Factor, Autonomy Time, Working Mode, History Log Events, Fault Condition and Temperature. Output Current / Load %, Load Power KVA / KW, Load Power Factor, Load Crest Factor, Battery Voltage / Current |
Event Log History | 500 Events |
Temperature | Operating: 0~45°C, Storage: -10ºC ~ 55ºC |
Humidity / Altitude | 0~95% RH Non-condersing / <1500 M |
Noise | Low Audible Noise Level |
Quality | ISO 9000, ISO 14001, OHSAS 18001, ISO 27001, RoHS |
Safety | IEC/EN62040-1 |
EMC / Performance | IEC/EN62040-2; IEC/EN62040-3, Complying to CE |
Standard | RS-232 / RS-485 |
Optional | SNMP / ModBus / Dry Contact |
Monitoring Software | NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000 / MAKnet |
© Copyright Adhunik Electric Company. All Rights Reserved.